xian-ncc-da-message/protos/device_status.proto

234 lines
6.4 KiB
Protocol Buffer
Raw Normal View History

2023-06-09 10:41:43 +08:00
syntax = "proto3";
package state; //模型的可变的状态数据
option java_package = "club.joylink.xiannccda.dto.protos";
option java_outer_classname = "DeviceStatusProto";
message Rtu{
bool ipRtuStusDown = 1;
bool ipRtuStusInLocalCtrl = 2;
bool ipRtuStusInCentralCtrl = 3;
bool ipRtuStusInEmergencyCtrl = 4;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
2023-06-09 11:09:37 +08:00
string id = 5;
2023-06-09 10:41:43 +08:00
}
message Station{
bool ipStaStusTermMode1 = 1;
bool ipStaStusTermMode2 = 2;
bool ipStaStusTermMode3 = 3;
bool ipStaStusTermMode4 = 4;
bool ipStaStusTermMode5 = 5;
bool ipStaStusTermMode6 = 6;
bool ipStaStusExpectTermMode1 = 7;
bool ipStaStusExpectTermMode2 = 8;
bool ipStaStusExpectTermMode3 = 9;
bool ipStaStusExpectTermMode4 = 10;
bool ipStaStusExpectTermMode5 = 11;
bool ipStaStusExpectTermMode6 = 12;
bool ipStaStusInCycle1 = 13;
bool ipStaStusInCycle2 = 14;
bool ipStaStusInCycle3 = 15;
bool ipStaStusInCycle4 = 16;
bool ipStaStusInCycle5 = 17;
bool ipStaStusInCycle6 = 18;
bool ipStaStusExpectCycle1 = 19;
bool ipStaStusExpectCycle2 = 20;
bool ipStaStusExpectCycle3 = 21;
bool ipStaStusExpectCycle4 = 22;
bool ipStaStusExpectCycle5 = 23;
bool ipStaStusExpectCycle6 = 24;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 25;
2023-06-09 10:41:43 +08:00
}
message Signal{
bool redOpen = 1;
bool redFlash = 2;
bool greenOpen = 3;
bool greenFlash = 4;
bool yellowOpen = 5;
bool yellowFlash = 6;
bool whiteOpen = 7;
bool whiteFlash = 8;
bool blueOpen = 9;
bool blueFlash = 10;
bool fleetMode = 11;
bool ctrlFleetMode = 12;
bool autoMode = 13;
bool ctrlAutoMode = 14;
bool extinguish = 15;
bool approachLock = 16;
bool protectRoute = 17;
bool autoRouteDisable = 18;
bool callon = 19;
bool yellowYellow = 20;
bool yellowGreen = 21;
bool blocked = 22;
bool lampFailure = 23;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 24;
2023-06-09 10:41:43 +08:00
}
message Entry{
bool dirLeft = 1;
bool dirRight = 2;
bool dirLocked = 3;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 4;
2023-06-09 10:41:43 +08:00
}
message Switch{
bool ipSingleSwitchStusCiOccupied = 1;
bool ipSingleSwitchStusCbtcOccupied = 2;
bool ipSingleSwitchStusLocked = 3;
bool ipSingleSwitchStusFailLocked = 4;
bool ipSingleSwitchStusNormal = 5;
bool ipSingleSwitchStusReverse = 6;
bool ipSingleSwitchStusBlocked1 = 7;
bool ipSingleSwitchStusJammed = 8;
bool ipSingleSwitchStusExpectLock = 9;
bool ipSingleSwitchStusExpectUnlock = 10;
bool ipSingleSwitchStusExpectNormal = 11;
bool ipSingleSwitchStusExpectReverse = 12;
bool ipSingleSwitchStusExpectBlock = 13;
bool ipSingleSwitchStusExpectUnblock = 14;
bool ipSingleSwitchStusInRoute = 15;
bool ipSingleSwitchStusManualMode = 16;
bool ipSingleSwitchStusCut = 17;
bool ipSingleSwitchStusAtcInvalid = 18;
bool ipSingleSwitchStusOverlap = 19;
bool ipSingleSwitchStusTsrCbtcMain = 20;
bool ipSingleSwitchStusTsrCbtcNormal = 21;
bool ipSingleSwitchStusTsrCbtcReverse = 22;
bool ipSingleSwitchStusTsrBmMain = 23;
bool ipSingleSwitchStusTsrBmNormal = 24;
bool ipSingleSwitchStusTsrBmReverse = 25;
bool ipSingleSwitchStusBlocked2 = 26;
bool ipSingleSwitchStusLostIndication = 27;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 28;
2023-06-09 17:30:27 +08:00
//限速值KM/H
int32 speedLimit = 29;
2023-06-09 10:41:43 +08:00
}
message Track{
bool ciOccupied = 1;
bool cbtcOccupied = 2;
bool locked = 3;
bool failLocked = 4;
bool expectLock = 5;
bool expectUnlock = 6;
bool inRoute = 7;
bool cut = 8;
bool atcInvalid = 9;
bool overlap = 10;
bool blocked = 11;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 12;
2023-06-09 10:41:43 +08:00
}
message Platform{
bool emergstop = 1;
bool trainberth = 2;
bool close = 3;
bool upHold = 4;
bool downHold = 5;
bool upOccHold = 6;
bool downOccHold = 7;
bool psdOpen = 8;
bool psdCut = 9;
bool upSkipstop = 10;
bool downSkipstop = 11;
bool upTrainSkipstop = 12;
bool downTrainSkipstop = 13;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 14;
2023-06-09 17:30:27 +08:00
//下一区间运行时间
int32 nextSectionRunTime = 15;
//下一区间运行等级
int32 nextSectionRunLevel = 16;
2023-06-09 10:41:43 +08:00
}
message Scada{
bool scadaOn = 1;
bool scadaSinglePower = 2;
bool scadaUnkown = 3;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 4;
2023-06-09 10:41:43 +08:00
}
message WaterProofDoor{
bool doorClosed = 1;
bool doorExpectClose = 2;
bool doorAgreeClosed = 3;
bool doorClosing = 4;
bool doorOpenLock = 5;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 6;
2023-06-09 10:41:43 +08:00
}
message WorkArea{
bool ipStusWorkAreaEnable = 1;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 2;
2023-06-09 10:41:43 +08:00
}
message Gama{
bool ipStusGamaDisable = 1;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 2;
2023-06-09 10:41:43 +08:00
}
message TrainMode{
bool ipModeTrainTypeManual = 1;
bool ipModeTrainTypeHead = 2;
bool ipModeTrainTypeSpecial = 3;
bool ipModeTrainTypeSchedule = 4;
bool ipModeTrainTypeRoute = 5;
bool ipModeTrainTypeShuttle = 6;
bool ipModeTrainTypeLineup = 7;
bool ipModeTrainSchdEarly = 8;
bool ipModeTrainSchdLate = 9;
bool ipModeTrainSkipstop = 10;
bool ipModeTrainCbtcMode = 11;
bool ipModeTrainAtpCut = 12;
bool ipModeTrainBerthed = 13;
bool ipModeTrainStoped = 14;
bool ipModeTrainHolded = 15;
bool ipModeTrainItama = 16;
bool ipModeTrainDirUp = 17;
bool ipModeTrainDirDown = 18;
bool ipModeTrainDirHeadUp = 19;
bool ipModeTrainDirHeadDown = 20;
bool ipModeTrainDoorOpen = 21;
bool ipModeTrainRsAlarm = 22;
bool ipModeTrainDoorAlarm = 23;
bool ipModeTrainEbAlarm = 24;
bool ipModeTrainIntegrityAlarm = 25;
bool ipModeTrainDriveModeAm = 26;
bool ipModeTrainDriveModeCm = 27;
bool ipModeTrainDriveModeRmf = 28;
bool ipModeTrainDriveModeDto = 29;
bool ipModeTrainDriveModeAtb = 30;
bool ipModeTrainDriveBlockAm = 31;
bool ipModeTrainDriveBlockCm = 32;
bool ipModeTrainDriveModeRmr = 33;
bool ipModeTrainDriveModeWash = 34;
2023-06-09 11:07:27 +08:00
//设备唯一识别码,一般为设备名称
string id = 35;
2023-06-09 10:41:43 +08:00
}
2023-06-09 17:30:27 +08:00
//////////////////////////////////////////////////////////////////////
//2.7.2 信息源网络状态消息
//NCC FEP与OCC FEP 间的网络连接状态
message OccNccFepNetwork{
//当前线路号
string id = 1;
//true 代表与当前线路号的信息源(server)连接正常
//false 代表断开
bool active = 2;
}